Difference between revisions of "Unbalanced"
Brad Johnson (talk | contribs) (Created page with "==Overview== The term "<nowiki>Unbalanced</nowiki>" is used to describe connections that are not "balanced" and employ a conductor held at "signal ground" potential to act as...") |
Brad Johnson (talk | contribs) |
||
(7 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
==Overview== | ==Overview== | ||
− | The term "<nowiki>Unbalanced</nowiki>" is used to describe connections that are not "[[balanced]]" and employ a conductor held at "signal ground" potential to act as a "signal return." | + | The term "<nowiki>Unbalanced</nowiki>" is used to describe connections that are not "[[balanced]]" and employ a conductor held at "signal [[ground]]" potential to act as a [[signal return]]. |
+ | |||
+ | ==Basics== | ||
+ | Any circuit must have a "path" for the current flowing in it to both "go to" the receiving device (or "load") and "return from" it. In the case of an unbalanced connection; even though the return conductor may be held at ground potential by being connected to the signal ground; it still can act as a return path for the signal ''current''. | ||
+ | |||
+ | By definition; this means that the signal ground of both the sending and receiving device must be connected together via the unbalanced connection; and this can lead to issues caused by other "interference" currents also flowing on this path. This is why [[balanced]] connections are used in audio as a means of eliminating these sources of interference. | ||
+ | |||
+ | Two sources of interference are: | ||
+ | #Induced noise | ||
+ | #[[Ground loop]]s" | ||
[[Category:Terminology]] | [[Category:Terminology]] | ||
[[Category:Analog interconnects]] | [[Category:Analog interconnects]] | ||
[[Category:Digital interconnects]] | [[Category:Digital interconnects]] |
Latest revision as of 17:49, 20 February 2017
Overview
The term "Unbalanced" is used to describe connections that are not "balanced" and employ a conductor held at "signal ground" potential to act as a signal return.
Basics
Any circuit must have a "path" for the current flowing in it to both "go to" the receiving device (or "load") and "return from" it. In the case of an unbalanced connection; even though the return conductor may be held at ground potential by being connected to the signal ground; it still can act as a return path for the signal current.
By definition; this means that the signal ground of both the sending and receiving device must be connected together via the unbalanced connection; and this can lead to issues caused by other "interference" currents also flowing on this path. This is why balanced connections are used in audio as a means of eliminating these sources of interference.
Two sources of interference are:
- Induced noise
- Ground loops"